Tilting Valve Test Bench which claws clamping with tilt ability is for Testing of Pressure Shut-off flow valves. 
Clamping of RF or RTJ valve could be executed in the real working conditions. The clamping is hydraulic on/off type. The auto-centering movement and plateau tilting is controlled manually. 
Tilting Valve Test Bench clamp fixtures are designed to clamp and test valves, fittings and related pressure bearing parts between centers. Hydrostatic or pneumatic seat testing can be performed from both sides without removing the valve from the clamp fixture. Moreover, the fixture can be set horizontal, so the test valve can be easily loaded from top with a overhead crane. The fixture can tilt to vertical position for testing.

CONFORMITY WITH STANDARD OF TESTS: API 598; DIN EN 12266; ISO 5208; ASME B 16.5; ASTME 1003-05; GOST 5762-2002; GOST 9544-2005.

Tilting Valve Testing including: Strength test of valve housing/valve body, trim leakage test, Leakage test of spindle gland, Leakage test of gate and seat interface sealing

Connection: Flanged, Socket Weld, Butt Welded, Threaded, Nipple,Special Ended.

Test objects: Shut Off Valve

Test Media: water / air / nitrogen

Optional Items: Computer Registrations System, Safety Closure

Gate Test Bench Feature:

  • The auto-centering movement and plateau tilting is controlled manually.
  • Sealing of tested item is carried out by the hydraulic cylinder.
  • The fixture can be set horizontal, so the test valve can be easily loaded from top with a overhead crane. The fixture can tilt to vertical position for testing.
  • All water-wetted parts are corrosion-proof.
  • The bench is equipped with the water-collection tray.